The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Prepare to conduct compliance inspection.
|
|
OHS procedures for a given work area are identified, obtained and understood. Completed |
Evidence:
|
Established OHS risk control measures and procedures in preparation for the work are followed. Completed |
Evidence:
|
Safety hazards that have not previously been identified are documented and risk control measures devised and implemented in consultation with appropriate person(s). Completed |
Evidence:
|
Documentation or deemed to comply standard on which installation is based is reviewed and understood. Completed |
Evidence:
|
Appropriate person(s) are consulted to ensure the work is coordinated effectively with others involved on the work site. Completed |
Evidence:
|
Tools, equipment and testing devices needed to verify compliance are obtained in accordance with established procedures and checked for correct operation and safety. Completed |
Evidence:
|
Conduct compliance inspect.
|
|
OHS risk control measures and procedures for carrying out the work are followed. Completed |
Evidence:
|
The need to test or measure live is determined in strict accordance with OHS requirements and when necessary conducted within established safety procedures. Completed |
Evidence:
|
Circuits/machines/plant are checked as being isolated where necessary in strict accordance OHS requirements and procedures. Completed |
Evidence:
|
Detailed inspection of the consumer’s mains and main switchboard is conducted methodically to ascertain compliance of protection, metering, earthing, circuit arrangements and markings. Completed |
Evidence:
|
Detailed inspection of circuits is conducted methodically to ascertain the compliance of the installed wiring, accessories, switchgear / control gear and current-using devices. Completed |
Evidence:
|
Where deemed necessary, evidence that electrical equipment complies with safety requirements is sought from appropriate person(s) and sighted. Completed |
Evidence:
|
Detailed inspection is conducted to verify compliance of earthing, insulation, polarity, circuit connections and operation of Residual current devices. Completed |
Evidence:
|
Fault-loop impedance is ascertained as being sufficiently low by testing, calculation or deemed to comply with arrangement of the installation. Completed |
Evidence:
|
Methods for dealing with unexpected situations are selected on the basis of safety and specified work outcomes. Completed |
Evidence:
|
Act and report on inspection findings.
|
|
OHS work completion risk control measures and procedures are followed. Completed |
Evidence:
|
Non-compliance defects are identified with appropriate clauses in regulatory standards and documented in accordance with established procedures. Completed |
Evidence:
|
Actions are taken as a result of non-compliance within the scope of inspection responsibilities and authority and documented. Completed |
Evidence:
|
Inspection report is made and issued to appropriate person(s) in accordance with established procedures. Completed |
Evidence:
|