NTISthis.com

Evidence Guide: UEENEEH123A - Fault find and repair microwave heating apparatus

Student: __________________________________________________

Signature: _________________________________________________

Tips for gathering evidence to demonstrate your skills

The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

UEENEEH123A - Fault find and repair microwave heating apparatus

What evidence can you provide to prove your understanding of each of the following citeria?

Prepare to find and repair faults.

  1. OHS procedures for a given work area are identified, obtained and understood.
  2. OHS risk control measures and procedures are followed in preparation for the work.
  3. The nature of the fault is obtained from documentation, work supervisor and customer to establish the scope of work to be undertaken.
  4. Advice is sought from the work supervisor to ensure the work is co-ordinated effectively with others.
  5. Sources of materials that may be required for the work are established in accordance with established procedures.
  6. Tools, equipment and testing devices needed to carry out the work are obtained in accordance with established procedures and checked for correct operation and safety.
OHS procedures for a given work area are identified, obtained and understood.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

OHS risk control measures and procedures are followed in preparation for the work.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

The nature of the fault is obtained from documentation, work supervisor and customer to establish the scope of work to be undertaken.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Advice is sought from the work supervisor to ensure the work is co-ordinated effectively with others.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Sources of materials that may be required for the work are established in accordance with established procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Tools, equipment and testing devices needed to carry out the work are obtained in accordance with established procedures and checked for correct operation and safety.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Find and repair faults.

  1. OHS risk control measures and procedures for carrying out the work are followed.
  2. The need to test or measure live is determined in strict accordance with OHS requirements and when necessary conducted within established safety procedures.
  3. Apparatus is checked as being isolated where necessary in strict accordance OHS requirements and procedures.
  4. Fault finding is approached methodically drawing on knowledge of microwave heating apparatus using measured and calculated values of operating parameters and referenced to manufacturer’s specifications.
  5. Equipment components are dismantled where necessary and parts stored to protect them against loss or damage.
  6. Faulty components are rechecked and their fault status confirmed.
  7. Faulty components are readjusted or replace in accordance with established procedures.
  8. Effectiveness of the repaired component is tested in accordance with established procedures.
  9. Apparatus is reassembled, finally tested and prepared for return to customer.
  10. Unexpected situations are dealt with safely and with the approval of an authorised person.
  11. Fault finding and repair activities are carried out efficiently without waste of materials or damage to apparatus and the surrounding environment or services and using sustainable energy practices.
OHS risk control measures and procedures for carrying out the work are followed.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

The need to test or measure live is determined in strict accordance with OHS requirements and when necessary conducted within established safety procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Apparatus is checked as being isolated where necessary in strict accordance OHS requirements and procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Fault finding is approached methodically drawing on knowledge of microwave heating apparatus using measured and calculated values of operating parameters and referenced to manufacturer’s specifications.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Equipment components are dismantled where necessary and parts stored to protect them against loss or damage.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Faulty components are rechecked and their fault status confirmed.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Faulty components are readjusted or replace in accordance with established procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Effectiveness of the repaired component is tested in accordance with established procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Apparatus is reassembled, finally tested and prepared for return to customer.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Unexpected situations are dealt with safely and with the approval of an authorised person.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Fault finding and repair activities are carried out efficiently without waste of materials or damage to apparatus and the surrounding environment or services and using sustainable energy practices.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Completion and report fault finding and repair activities.

  1. OHS work completion risk control measures and procedures are followed.
  2. Work area is cleaned and made safe in accordance with established procedures.
  3. Written justification is made for repairs to apparatus including components and materials used.
  4. Acceptance that the reported fault(s) have been repaired is sought from an appropriate person in accordance with established procedures.
OHS work completion risk control measures and procedures are followed.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Work area is cleaned and made safe in accordance with established procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Written justification is made for repairs to apparatus including components and materials used.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Acceptance that the reported fault(s) have been repaired is sought from an appropriate person in accordance with established procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

9)

Overview of Assessment

9.1)

Critical aspects of evidence required to demonstrate competency in this unit

9.2)

Context of and specific resources for assessment

9.3)

Method of assessment

9.4)

Concurrent assessment and relationship with other units

9.5)

Required Skills and Knowledge

8) This describes the essential skills and knowledge and their level, required for this unit.

Evidence shall show that knowledge has been acquired of safe working practices and finding and repairing faults in microwave heating apparatus.

All knowledge and skills detailed in this unit should be contextualised to current industry practices and technologies.

KS01-EH123A Microwave heating apparatus

Evidence shall show an understanding of microwave heating apparatus fault finding and repair, applying safe working practices and relevant Standards, Codes and Regulations to an extent indicated by the following aspects:

T1. Propagation of electromagnetic waves through the atmosphere, microwave frequency bands

T2. Microwave heating devices encompassing:

Components

Operating parameters and constraints

Measurements, test equipment and testing techniques

T3. EMI/EMC, generation, suppression and reduction.

Range Statement

10) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance.

This unit shall be demonstrated in relation to finding and repairing at least four faults in two different microwave heating devices.

Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1.