The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Prepare to calibrate, adjust and test measuring instruments
|
|
OHS procedures for a given work area are identified, obtained and understood Completed |
Evidence:
|
Established OHS risk control measures and procedures are followed in preparation for the work. Completed |
Evidence:
|
Safety hazards that have not previously been identified are noted, and established risk control measures are implemented. Completed |
Evidence:
|
Appropriate personnel are consulted to ensure the work is coordinated effectively with others involved on the work site Completed |
Evidence:
|
Instrument parameters are determined by reviewing process specification and equipment manuals. Completed |
Evidence:
|
Tools, equipment and testing devices needed for the work are obtained in accordance with established procedures and checked for correct operation and safety Completed |
Evidence:
|
Calibrate, adjust and test measuring instruments
|
|
OHS risk control measures and procedures for carrying out the work are followed. Completed |
Evidence:
|
Calibration testing/measuring arrangement is connected and set up in accordance with manufacturer’s instructions and certification requirements for a particular instrument. Completed |
Evidence:
|
Factors effecting instrument error are determined and taken into account in the calibration process. Completed |
Evidence:
|
Instrument set-point is established and error adjustments are in accordance with manufacture’s and compliance specification Completed |
Evidence:
|
Instrument is tested and adjustment made as necessary to ensure instrument meets calibration requirements. Completed |
Evidence:
|
Established methods for dealing with unexpected situations are discussed with appropriate person or persons and documented. Completed |
Evidence:
|
Unexpected situations are dealt with safely and with the approval of an authorised person. Completed |
Evidence:
|
Ongoing checks of the quality of process output are undertaken to ensure control loop is tuned as required. Completed |
Evidence:
|
Calibration is carried out efficiently without waste of materials or damage to apparatus, the surrounding environment or services and using sustainable energy principles. Completed |
Evidence:
|
Completion and report calibration activities
|
|
OHS risk control work completion measures and procedures are followed. Completed |
Evidence:
|
Work site is cleaned and made safe in accordance with established procedures. Completed |
Evidence:
|
Calibration is documented in accordance with certification requirements. Completed |
Evidence:
|