The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

UEENEEJ190A - Select basic commercial refrigeration system equipment, components and accessories

What evidence can you provide to prove your understanding of each of the following citeria?

Prepare to select basic commercial refrigeration system equipment and components

  1. The extent and nature of the refrigeration installation is determined from job specifications.
  2. Safety and other regulatory requirements to which the refrigeration system shall comply, are identified, obtained and understood
The extent and nature of the refrigeration installation is determined from job specifications.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Safety and other regulatory requirements to which the refrigeration system shall comply, are identified, obtained and understood

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Develop pipe work arrangements

  1. The intended location of refrigeration equipment is determined from job specifications and site drawings or deemed to comply arrangements.
  2. Pipe work arranged to ensure safe and functional operation of the system.
  3. Pipe work is arranged to comply with technical standards and job specifications and requirements.
The intended location of refrigeration equipment is determined from job specifications and site drawings or deemed to comply arrangements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Pipe work arranged to ensure safe and functional operation of the system.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Pipe work is arranged to comply with technical standards and job specifications and requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Select basic commercial refrigeration system equipment and components

  1. Pipe and tubing is selected for suitability for the environments in which it is to be installed
  2. Pipe and tubing is sized to meet refrigeration parameters and capacity requirements for the refrigerant to be used.
  3. Pipe and tubing quantities are determined from equipment location diagrams and job specifications.
  4. Refrigeration system equipment and components are selected to meet load requirements based on calculated or deemed-to-comply solutions.
  5. Refrigerant liquid expansion valves are selected to meet functional, specified and regulatory requirements.
  6. Automatic control devices are selected to meet functional, specified, regulatory requirements. And current, voltage and IP ratings.
  7. Evidence is obtained that the selected refrigeration equipment and components comply with all requirements.
Pipe and tubing is selected for suitability for the environments in which it is to be installed

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Pipe and tubing is sized to meet refrigeration parameters and capacity requirements for the refrigerant to be used.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Pipe and tubing quantities are determined from equipment location diagrams and job specifications.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Refrigeration system equipment and components are selected to meet load requirements based on calculated or deemed-to-comply solutions.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Refrigerant liquid expansion valves are selected to meet functional, specified and regulatory requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Automatic control devices are selected to meet functional, specified, regulatory requirements. And current, voltage and IP ratings.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Evidence is obtained that the selected refrigeration equipment and components comply with all requirements.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Document selection of system equipment and components

  1. Reasons for selections made, including calculations, are documented in accordance with established procedures.
  2. Refrigeration installation arrangement and specifications for all selected items are documented in accordance with established procedures and forwarded to appropriate person(s).
Reasons for selections made, including calculations, are documented in accordance with established procedures.

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Refrigeration installation arrangement and specifications for all selected items are documented in accordance with established procedures and forwarded to appropriate person(s).

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Evidence Guide

9) The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package. .

The Evidence Guide forms an integral part of this Unit. It must be used in conjunction with all parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.

Overview of Assessment

9.1)

Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the industry-preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. In some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accordance with industry and regulatory policy.

Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.

The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be 'rich' in nature to minimise error in judgment.

Activities associated with normal everyday work influence decisions about how/how much the data gathered will contribute to its 'richness'. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.

Critical aspects of evidence required to demonstrate competency in this unit

9.2)

Before the critical aspects of evidence are considered all prerequisites must be met.

Evidence for competence in this unit shall be considered holistically. Each Element and associated performance criteria shall be demonstrated on at least two occasions in accordance with the 'Assessment Guidelines - UEE07 '. Evidence shall also comprise:

A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:

Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the performance criteria and range statement

Apply sustainable energy principles and practices as specified in the performance criteria and range statement

Demonstrate an understanding of the essential knowledge and associated skills as described in this unit. It may be required by some jurisdictions that RTOs provide a percentile graded result for the purpose of regulatory or licensing requirements.

Demonstrate an appropriate level of skills enabling employment

Conduct work observing the relevant Anti Discrimination legislation, regulations, polices and workplace procedures

Demonstrated consistent performance across a representative range of contexts from the prescribed items below:

Select basic commercial refrigeration system equipment and components as described in 8) and including:

A

Arranging pipe work to comply with regulatory and functional requirements.

B

Selecting appropriate type, size and quantity of pipe and tubing

C

Selecting refrigeration equipment and components that meets load requirements

D

Selecting automatic control devices that meet functional and regulatory requirements.

E

Documenting pipe work arrangement, specification for items selected and reasons for the selections made

F

Dealing with unplanned events by drawing on essential knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items

Context of and specific resources for assessment

9.3)

This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:

OHS policy and work procedures and instructions.

Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this unit.

These should be part of the formal learning/assessment environment.

Note:

Where simulation is considered a suitable strategy for assessment, conditions must be authentic and as far as possible reproduce and replicate the workplace and be consistent with the approved industry simulation policy.

Evidence should show demonstrated competency in selecting refrigerant pipe/tube, accessories and associated controls.

Method of assessment

9.4)

This unit shall be assessed by methods given in Volume 1, Part 3 'Assessment Guidelines'.

Note:
Competent performance with inherent safe working practices is expected in the Industry to which this unit applies. This requires assessment in a structured environment which is intended primarily for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the essential knowledge and skills described in this unit.

Concurrent assessment and relationship with other units

9.5)

For optimisation of training and assessment effort, competency development in this unit may be arranged concurrently with unit:

UEENEED001B

Use basic computer applications

Required Skills and Knowledge

7) This describes the essential skills and knowledge and their level, required for this unit.

Evidence shall show that knowledge has been acquired of safe working practices and selecting basic commercial refrigeration system equipment and components.

All knowledge and skills detailed in this unit should be contextualised to current industry practices and technologies.

KS01-EJ190A

Basic commercial refrigeration system equipment, and components and accessories selection

Evidence shall show an understanding of basic commercial refrigeration system components and piping selection, applying safe working practices and relevant Standards, Codes and Regulations to an extent indicated by the following aspects:

T1 Calculation of capacity in heat exchangers:

Q = UA (LMTD)

Q = mc∆t

Q = m ∆h

T2 Evaporators

commercial types and applications

coil bypass factor

effects of evaporator TD on space humidity

effects of air circulation on product conditions

selection criteria and selection tables

T3 Condensers

commercial types and applications

effects of ambient conditions

condenser control

heat rejection factor

condenser TD

selection criteria and selection tables

T4 Compressors

types and applications

capacity

displacement

volume flow rate

theoretical capacity

total volumetric efficiency

effect of operating conditions, including suction pressure drop and superheating

actual capacity

power

theoretical requirement

effects of operating conditions

actual requirements

post defrost loads

pull down torque requirements, high, medium and low back pressure compressors

selection tables, motor selection

T5 Refrigerant flow controls

types, operation and applications

effects from sub-cooling

distributor types, operation and applications

selection tables

T6 System load balance point

graphical representation

T7 Line sizing and design

quick selection tables

velocity tables

pressure drop in lines and fittings

oil migration stabilisation

refrigerant velocity

effect of varying system capacity

oil traps

risers

liquid migration

T8 Automatic controls

fin spacing, suction temp to evaporator suction

hot-gas bypass valves

electronic control of valves PLC control

refrigerant regulating valves

solenoid valves

condenser pressure regulating valves

evaporator pressure regulating valves

crankcase pressure regulating valves

cycling controls

pressure-stats

thermostats,

defrost controls

monitoring and alarm controls

refrigeration automation systems

control strategies

control modes

Range Statement

8) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance.

This unit must be demonstrated in relation to the selection of basic commercial refrigeration system equipment and components, pipe work and controls for two different refrigeration systems. These include the following; refrigerant, condensing unit, evaporator, refrigerant controls, accessories, refrigerant and condensate pipe work, and system controls selection of refrigerant pipe/tube, accessories and associated controls.

Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1.