NTISthis.com

Evidence Guide: UEERA0009 - Audit energy use for commercial HVAC/R systems

Student: __________________________________________________

Signature: _________________________________________________

Tips for gathering evidence to demonstrate your skills

The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!

From the Wiki University

 

UEERA0009 - Audit energy use for commercial HVAC/R systems

What evidence can you provide to prove your understanding of each of the following citeria?

Prepare to audit energy use for a commercial HVAC/R application

  1. WHS/OHS processes and workplace procedures for a given work area are identified and applied
WHS/OHS processes and workplace procedures for a given work area are identified and applied

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

WHS/OHS risk control measures and workplace procedures are followed in preparation for the work

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

HVAC/R system assessment and testing area are checked for safety hazards and risk control measures implemented in accordance with safety policy and workplace procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Relevant documentation is obtained and read to determine performance/certification assessment requirements

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Advice is sought from the work supervisor to ensure work is coordinated effectively with others

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Tools, testing devices and materials needed to carry out the work are obtained and checked for correct operation and safety

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Audit energy use for a commercial HVAC/R application

  1. WHS/OHS risk control measures and workplace procedures for carrying out the work are followed
WHS/OHS risk control measures and workplace procedures for carrying out the work are followed

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Circuits/apparatus/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

HVAC/R system performance and energy efficiency requirements and assessment methods are applied to the audit process

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

HVAC/R apparatus assessment and tests are set up in accordance with established test methods and workplace procedures for each parameter being audited

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

HVAC/R system assessment and tests are carried out methodically and results and required actions systematically noted

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Unexpected situations are dealt with safely in accordance with workplace procedures with the approval of an authorised person/s in a manner that minimises risk to personnel and equipment

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Auditing is carried out without damage to systems, circuits, the surrounding environment or services using sustainable energy practices

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Document auditing activities and results

  1. WHS/OHS work completion risk control measures and workplace procedures are followed
WHS/OHS work completion risk control measures and workplace procedures are followed

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Worksite is cleaned and made safe in accordance with workplace procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessment and test results are evaluated, non-compliance issues identified, and appropriate actions determined and documented

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessment test results and recommendations on non-compliance issues are documented and reported to appropriate person/s in accordance with workplace procedures

Completed
Date:

Teacher:
Evidence:

 

 

 

 

 

 

 

Assessed

Teacher: ___________________________________ Date: _________

Signature: ________________________________________________

Comments:

 

 

 

 

 

 

 

 

Instructions to Assessors

Required Skills and Knowledge

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions on at least one occasion and include:

interpreting performance/certification requirements correctly

setting up and conducting appropriate system assessments and tests

identifying non-compliance issues

reporting assessment and test results and non-compliance issues and recommendations appropriately

dealing with unplanned events

analysing results from test data, including:

analysing electricity tariffs and implications

analysing total consumption versus peak load

comparing against industry standards

reviewing current practices against ideal

applying relevant work health and safety (WHS)/occupational health and safety (WHS/OHS) workplace procedures and practices, including using risk control measures

applying sustainable energy principles and practices

auditing energy use for commercial heating, ventilation and air conditioning/refrigeration (HVAC/R) system, including:

documenting auditing activities results and appropriate actions

planning audit energy use for a commercial HVAC/R application.

Evidence required to demonstrate competence in this unit must be relevant to and satisfy all of the requirements of the elements, performance criteria and range of conditions and include knowledge of:

HVAC/R energy audits, safe working practices and relevant standards, codes and regulations, including:

identification of major energy consuming plant:

review of HVAC/R system components

methods of energy conservation:

review of energy conserving strategies

house keeping

time schedules

good maintenance practices:

filters, fans, appropriate set points and dead bands

HVAC/R system control:

night cycle

optimum stop/start

purge cycles

chiller/boiler/cooling tower sequencing

economy cycles (based on temperature or enthalpy)

supply air reset

condenser water temperature reset

electrical load control:

power demand control

load limiting

load shedding

set point relaxation

ventilation cycles

tests and data collection procedures:

use of building management system for data collection (trending)

use of data recorders (loggers)

monitoring of building operations generally

analysis of results from test data:

comparison against standards (BOMA)

revision of current practices against ideal

total consumption vs. peak load

electricity tariffs and implications

methods of reducing energy usage:

plant retrofits

controls - application of strategies

plant - fixed OA to economy, boiler to electric reheat, constant volume to variable air volume (VAV) and cost-benefit (payback)

relevant manufacturer specifications

relevant safe work method statements (SWMS)/job safety assessments or risk mitigation processes

relevant WHS/OHS legislated requirements

relevant workplace documentation

relevant workplace policies and procedures.

Range Statement

Range is restricted to essential operating conditions and any other variables essential to the work environment.

Non-essential conditions may be found in the UEE Electrotechnology Training Package Companion Volume Implementation Guide.

Auditing energy use must include at least the following:

two different commercial HVAC/R systems