The important thing to remember when gathering evidence is that the more evidence the better - that is, the more evidence you gather to demonstrate your skills, the more confident an assessor can be that you have learned the skills not just at one point in time, but are continuing to apply and develop those skills (as opposed to just learning for the test!). Furthermore, one piece of evidence that you collect will not usualy demonstrate all the required criteria for a unit of competency, whereas multiple overlapping pieces of evidence will usually do the trick!
From the Wiki University
What evidence can you provide to prove your understanding of each of the following citeria?
Plan and prepare for the work
|
|
Work requirements are identified from request/work orders or equivalent and clarified/confirmed with appropriate parties or by site inspection Completed |
Evidence:
|
Occupational Health and Safety standards, statutory requirements, relevant Australian standards, codes of practice, manufacturers' specifications, environmental requirements and enterprise procedures are identified, applied and monitored throughout the work procedure Completed |
Evidence:
|
Resources required to satisfy the work plan are identified, obtained and inspected for compliance with the job specifications Completed |
Evidence:
|
Relevant plans, drawings and texts are selected and interpreted in accordance with the work plan Completed |
Evidence:
|
Correct size, type and quantity of materials/components are determined, obtained and inspected for compliance with the job specifications Completed |
Evidence:
|
Work is planned in detail including sequencing and prioritising and considerations made where appropriate for the maintenance of plant security and capacity in accordance with system/site requirements Completed |
Evidence:
|
Coordination requirements, including requests for isolations where appropriate, are resolved with others involved, affected or required by the work Completed |
Evidence:
|
Potential hazards are identified and prevention and/or control measures are selected in accordance with the work plan and site procedures Completed |
Evidence:
|
Work area is prepared in accordance with work requirements and site procedures Completed |
Evidence:
|
Where appropriate, the teams and individuals roles and responsibilities within the team are identified and, where required, assist in the provision of on-the-job training Completed |
Evidence:
|
Remove valves for maintenance
|
|
Required isolations are confirmed where appropriate in accordance with site requirements Completed |
Evidence:
|
Valve is disconnected in accordance with the work plan Completed |
Evidence:
|
Valve is removed in a manner which will assist in replacement in accordance with the work plan Completed |
Evidence:
|
Valve is inspected for abnormalities in accordance with the work plan. Completed |
Evidence:
|
Perform valve maintenance
|
|
Maintenance is performed in accordance with manufacturers specifications and the work plan Completed |
Evidence:
|
Valve is dismantled, clearly marked for identification and relevant sketches drawn in accordance with the work plan Completed |
Evidence:
|
Components are correlated in preparation for re-assembly in accordance with manufacturer drawings/manuals Completed |
Evidence:
|
New components are inspected to ensure compliance with manufacturer specifications Completed |
Evidence:
|
Dimensional inspection is performed with precision measuring devices to ensure compliance with manufacturer specifications and site requirements Completed |
Evidence:
|
Components are reassembled for testing in accordance with manufacturer specifications and site requirements Completed |
Evidence:
|
Modifications/alterations are undertaken in accordance with manufacturer specifications and site requirements Completed |
Evidence:
|
Components are levelled, aligned, coupled and connected in accordance with manufacturer specifications and site requirements Completed |
Evidence:
|
Valves are pressure tested, monitored and adjusted if required in accordance with manufacturer specifications and the work plan Completed |
Evidence:
|
Replace/install valves
|
|
Site is prepared for valve replacement in accordance with the work plan Completed |
Evidence:
|
Valve is replaced in accordance with the work plan and manufacturer specifications Completed |
Evidence:
|
Valve is connected in accordance with the work plan and manufacturer specifications Completed |
Evidence:
|
Final job inspection is completed and any permits relinquished in accordance with the work plan Completed |
Evidence:
|
Complete the work
|
|
Work is completed and appropriate personnel notified in accordance with site/enterprise requirements Completed |
Evidence:
|
Work area is cleared of waste, cleaned, restored and secured in accordance with site/enterprise procedures Completed |
Evidence:
|
Plant, tools and equipment are maintained and stored in accordance with site/enterprise procedures Completed |
Evidence:
|
Work completion details are finalised in accordance with site/enterprise procedures Completed |
Evidence:
|