Conduct fumigation

Formats and tools

Unit Description
Reconstruct the unit from the xml and display it as an HTML page.
Assessment Tool
an assessor resource that builds a framework for writing an assessment tool
Assessment Template
generate a spreadsheet for marking this unit in a classroom environment. Put student names in the top row and check them off as they demonstrate competenece for each of the unit's elements and performance criteria.
Assessment Matrix
a slightly different format than the assessment template. A spreadsheet with unit names, elements and performance criteria in separate columns. Put assessment names in column headings to track which performance criteria each one covers. Good for ensuring that you've covered every one of the performance criteria with your assessment instrument (all assessement tools together).
Wiki Markup
mark up the unit in a wiki markup codes, ready to copy and paste into a wiki page. The output will work in most wikis but is designed to work particularly well as a Wikiversity learning project.
Evidence Guide
create an evidence guide for workplace assessment and RPL applicants
Competency Mapping Template
Unit of Competency Mapping – Information for Teachers/Assessors – Information for Learners. A template for developing assessments for a unit, which will help you to create valid, fair and reliable assessments for the unit, ready to give to trainers and students
Observation Checklist
create an observation checklist for workplace assessment and RPL applicants. This is similar to the evidence guide above, but a little shorter and friendlier on your printer. You will also need to create a seperate Assessor Marking Guide for guidelines on gathering evidence and a list of key points for each activity observed using the unit's range statement, required skills and evidence required (see the unit's html page for details)

Self Assessment Survey
A form for students to assess thier current skill levels against each of the unit's performance criteria. Cut and paste into a web document or print and distribute in hard copy.
Moodle Outcomes
Create a csv file of the unit's performance criteria to import into a moodle course as outcomes, ready to associate with each of your assignments. Here's a quick 'how to' for importing these into moodle 2.x
Registered Training Organisations
Trying to find someone to train or assess you? This link lists all the RTOs that are currently registered to deliver CPPPMT3011A, 'Conduct fumigation'.
Google Links
links to google searches, with filtering in place to maximise the usefulness of the returned results
Books
Reference books for 'Conduct fumigation' on fishpond.com.au. This online store has a huge range of books, pretty reasonable prices, free delivery in Australia *and* they give a small commission to ntisthis.com for every purchase, so go nuts :)


Elements and Performance Criteria

1

Access and assess work site.

1.1

Site environment is accessed according to company requirements.

1.2

Work order is reviewed according to company requirements and issues are clarified with appropriate persons.

1.3

Authority of client requesting fumigation services is confirmed according to company requirements.

1.4

Hazards are identified and risks controlled at work site according to company, legislative, occupational health and safety (OHS), and public health and safetyrequirements.

1.5

Work site and work site application characteristics are assessed according to legislative and company requirements.

1.6

Size and usage pattern of work site are determined to ensure safety of personnel and efficient use of equipment and fumigants.

1.7

Work site is assessed for access and security arrangements, according to legislative, OHS and company requirements.

2

Determine type and method of fumigation.

2.1

Types of organisms and commodities are confirmed according to company requirements.

2.2

Fumigation method is selected to suit types of organisms, work site and commodities according to manufacturer specifications and legislative, OHS, company and environmental requirements.

2.3

Type of fumigant is selected and accessed according to manufacturer specifications and client, environmental, legislative, OHS and company requirements.

2.4

Capacity to create fumigation conditions is established according to manufacturer specifications and environmental, legislative, OHS and company requirements.

2.5

Factors preventing completion of work order are identified and appropriate persons are promptly notified.

3

Prepare work site for fumigation.

3.1

Hazards of using fumigants at the work site are identified and risks controlled according to legislative, OHS and company requirements.

3.2

Appropriate personnel in adjoining properties and regulatory and other relevant authorities are advised of proposed fumigation according to legislative and company requirements.

3.3

Signage and barriers are installed, as required, to maximise protection of public health and safety during fumigation according to legislative and company requirements.

3.4

Security measures to control unauthorised access to work site during fumigation and prescribed non re-entry periods are implemented according to manufacturer specifications and legislative, OHS and company requirements.

3.5

Conditions to ensure that required concentration of fumigant is retained for required period within fumigation enclosure are created according to manufacturer specifications and public health and safety and company requirements.

4

Prepare equipment and fumigants.

4.1

Suitable personal protective equipment (PPE) is selected and used according to manufacturer specifications and legislative, OHS and company requirements.

4.2

Equipment for fumigation is selected according to manufacturer specifications and company requirements.

4.3

Calibration and operational effectiveness equipment is checked according to manufacturer specifications and company requirements.

4.4

Equipment is set up and adjusted to suit operator’s requirements according to manufacturer specifications and company requirements.

4.5

Selected fumigants are transported, and dosages calculated and prepared to control risk of non-target contamination or exposure according to manufacturer specifications and environmental, legislative, OHS and company requirements.

5

Apply fumigants.

5.1

Fumigation enclosure is treated using equipment, fumigants and fumigation methods according to manufacturer specifications and environmental, legislative, OHS and company requirements.

5.2

Airtight seal on fumigation enclosure is checked and adjusted, where applicable, according to manufacturer specifications and environmental, legislative, OHS and company requirements.

5.3

Fumigant escape is assessed to control impact on public health and safety, according to manufacturer specifications and environmental, legislative, OHS and company requirements.

5.4

Emergency response procedures are implemented when necessary according to environmental, legislative, OHS and company requirements.

6

Monitor fumigation.

6.1

Fumigation work site is monitored continuously to prevent unauthorised access and to maintain safe conditions according to manufacturer specifications and environmental, legislative, OHS and company requirements.

6.2

Fumigant concentrations are monitored and maintained over active period according to manufacturer specifications and environmental, legislative, OHS and company requirements.

6.3

Integrity of airtight seals is maintained, where applicable, throughout the active fumigation period according to manufacturer specifications and environmental, legislative, OHS and company requirements.

6.4

Ongoing assessment of fumigant escape is maintained to control impact on public health and safety according to manufacturer specifications and environmental, legislative, OHS and company requirements.

7

Ventilate fumigation enclosure.

7.1

Suitable conditions for ventilation are established to control risks to public health and safety according to manufacturer specifications and environmental, legislative, OHS and company requirements.

7.2

Approved method of safe release of fumigant is implemented according to manufacturer specifications and environmental, legislative, OHS and company requirements.

7.3

Fumigation enclosure is ventilated to remove fumigant in a safe and controlled manner according to manufacturer specifications and environmental, legislative, OHS and company requirements.

7.4

Fumigation enclosure and commodities are aerated according to manufacturer specifications and company requirements.

7.5

Fumigation enclosure and commodities are tested for evidence of residual fumigant according to manufacturer specifications and environmental, legislative, OHS and company requirements.

7.6

Client and other appropriate persons are notified of further risk control measures required according to manufacturer specifications and legislative, OHS and company requirements.

8

Restore work site.

8.1

Equipment, fumigants and waste are collected and removed according to environmental, legislative, OHS and company requirements.

8.2

Work site is restored according to work order and client, environmental and company requirements.

8.3

Signage and barriers are removed when work site is available for re-use, according to environmental, legislative, OHS and company requirements.

9

Clean, safety-check and store equipment and fumigants.

9.1

Equipment and PPE are cleaned and decontaminated according to manufacturer specifications and environmental, OHS and company requirements.

9.2

Equipment and PPE are safety-checked and required maintenance is recorded according to manufacturer specifications and OHS and company requirements.

9.3

Cleaned equipment and PPE are stored to allow ready access and re-use according to company requirements.

9.4

Fumigants are transported and stored according to manufacturer specifications and OHS and company requirements.

9.5

Collected waste is disposed of according to work order, manufacturer specifications and environmental, legislative, OHS and company requirements.

9.6

Exposed skin is treated to remove any contamination according to manufacturer specifications and OHS and company requirements.

10

Update regulatory and company documentation.

10.1

Regulatory and company documentation is completed and distributed according to environmental, legislative and company requirements.

10.2

Client records are updated according to company requirements.